AOAC Official Method 935.27 Malt Bushel Weight
First Action 1935
Final Action 1960
Method I
Place laboratory sample in filling hopper of Winchester tester,(Seedburo Equipment Co., 1022 W Jackson Blvd, Chicago, IL 60607, USA [available as filing hopper and stand No. 151, quart cup scale No. 8800, and strike-off stick No. 65]), open slide underneath,and let malt fill measuring cylinder to overflowing. Without jarring,level off with straight-edge longer than diameter of measuring cylinder,making one forward stroke consisting of 3 distinct zigzag motions.Weigh and report to nearest 100 g.